ford Workshop Repair Guides

Ford F-250 2WD Pickup V8-54L CNG Workshop Service & Repair Manuals

Initial Inspection and Diagnostic Overview|Page 4885 > < Initial Inspection and Diagnostic Overview|Page 4883
Page 3
background image

3. WARNING:  Always follow proper safety procedures while using press. 

Install the torque converter with the installed leak check tool into the Arbor press. Secure the press.

Apply enough force from the press to seal tool into the torque converter.

4. NOTE:  Use clean dry shop air.

Apply air pressure to valve on leak check tool.

5. With air pressure applied to valve, inspect for leaks at converter hub, seams and studs. A soap bubble solution may be applied around those areas

to aid in diagnosis. If leaks are present, replace converter.

Initial Inspection and Diagnostic Overview|Page 4885 > < Initial Inspection and Diagnostic Overview|Page 4883