ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 7290 > < Initial Inspection and Diagnostic Overview|Page 7288
Page 6
background image

Z6 CHECK FOR VOLTAGE TO CHECK THE TRAILER TOW STOP/TURN RELAY USING THE GROUND CIRCUIT

-

For the LH trailer turn lamp, measure the voltage between the trailer tow LH stop/turn relay pin 3, BJB face side and the trailer tow LH stop/turn
relay pin 2, circuit GD122 (BK), BJB face side.

-

Measure the voltage between the trailer tow RH stop/turn relay pin 3, BJB face side and the trailer tow RH stop/turn relay pin 2, circuit GD122
(BK), BJB face side.

-

Is the voltage greater than 10 volts?

Yes

REPAIR circuit GD122 (BK) for an open. TEST the system for normal operation.

No

REPAIR circuit CAT06 (YE) (LH trailer stop/turn) or circuit CAT09 (GN) (RH trailer stop/turn) for an open. TEST the system for normal operation.

-------------------------------------------------

Pinpoint Test AA: The Trailer Lamps Are Inoperative - Trailer Parking Lamps

Trailer Lamps

Pinpoint Tests

Pinpoint Test AA: The Trailer Lamps Are Inoperative - Trailer Parking Lamps

Refer to Wiring Diagram Set 95, Trailer/Camper Adapter for schematic and connector information.  See: Diagrams/Electrical Diagrams/Diagrams By
Number

Initial Inspection and Diagnostic Overview|Page 7290 > < Initial Inspection and Diagnostic Overview|Page 7288