ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Restraint Systems > < Vacuum Solenoid Valve HVAC|Locations|Page 9418
Page 1
background image

Vacuum Solenoid Valve HVAC: Service and Repair

AUTOMATIC TEMPERATURE CONTROL SOLENOID AND MANIFOLD

Removal and Installation

1. Remove the audio unit.

2. Disconnect the automatic temperature control (ATC) solenoid and manifold.

1

Disconnect the vacuum connector.

2

Disconnect the electrical connector.

3. Remove the screw and remove the ATC solenoid and manifold.
4. To install, reverse the removal procedure.

Restraint Systems > < Vacuum Solenoid Valve HVAC|Locations|Page 9418