Ambient Temperature Sensor / Switch HVAC: Service and Repair

REMOVAL

1. Remove the eight pin-type retainers and remove the upper radiator sight shield.

2. Remove the two upper pin-type retainers and position aside the air deflector.

3. Detach the ambient temperature sensor pin-type retainer.

4. Disconnect the electrical connector and remove the ambient temperature sensor.

INSTALLATION

1. To install, reverse the removal procedure.