Expansion Valve: Service and Repair

Auxiliary Climate Control

REMOVAL

1. Recover the refrigerant.
2. Remove the access panel from the RH rear quarter trim panel.
3. Remove the jack.

4. Remove the A/C lines from the A/C evaporator expansion valve.

1

Disconnect the A/C lines from the A/C evaporator expansion valve.

2

Disconnect the A/C evaporator expansion valve from the A/C evaporator core.

INSTALLATION

1. To install, reverse the removal procedure.

NOTE:  Lubricate the O-ring seals with PAG Refrigerant Compressor Oil (R-134a Systems) F7AZ-19589-DA (Motorcraft YN-12-C) or
equivalent meeting Ford specification WSH-M1C231-B.

2. Evacuate, leak test and charge the A/C system.