Lock may be displaced into an unlocked position; pull on the connector to verify the lock.

Deformed (enlarged) female terminals

1

Enlarged

2

Normal

Any probe entering the terminal may enlarge the contact spring opening creating an intermittent signal. Insert the correct mating terminal (Location A)
from the service kit and feel for a loose fit.

Electrical short inside the harness

1

Solder coated wire to ground

2

Harness protective tape

3

Intermittent short
Solder coated wire pierced through the insulation of another circuit

4

Grounding foil