12. Remove the pressure cutoff switch.
INSTALLATION
1. To install, reverse the removal procedure.
^
Install new O-ring seals lubricated in clean PAG oil.
^
Lubricate the refrigerant system with the correct amount of clean PAG oil.
2. Evacuate, leak test and charge the refrigerant system.