1. NOTE:  If the valve cover is not secured within 4 minutes, the sealant must be removed and the sealing area cleaned with metal surface cleaner.

Failure to follow this procedure can cause future oil leakage.

Apply a bead of silicone gasket and sealant in 2 places where the engine front cover meets the cylinder head.

2. Position the LH valve cover and new gasket on the cylinder head and tighten the 17 fasteners in the sequence shown

^

Tighten to 10 Nm (89 inch lbs.).

3. Position the engine wiring harness retainers onto the valve cover studs.
4. Position the positive crankcase ventilation (PCV) tube and connect the quick connect couplings. 

5. Position the degas bottle and install the 2 bolts.

^

Tighten to 10 Nm (89 inch lbs.).

6. Install the LH ignition coils. 

Valve Cover-RH|Page 2589 > < Valve Cover-RH|Page 2587