Removal

1. Remove the Air Cleaner (ACL) outlet pipe.

2. Remove the LH ignition coils.

3. Remove the oil level indicator and tube. For additional information, refer to Oil Level Indicator and Tube  See: Engine Lubrication/Engine Oil Dip

Stick - Dip Stick Tube/Service and Repair/Oil Level Indicator and Tube.

4. Disconnect the quick connect couplings and remove the PCV tube.

5. Disconnect the engine wiring harness retainers from the valve cover studs and position the wiring harness aside.

6. NOTICE: Do not use metal scrapers, wire brushes, power abrasive discs or other abrasive means to clean the sealing surfaces. These tools

cause scratches and gouges which make leak paths. Use a plastic scraping tool to remove all traces of old sealant.

NOTE: The bolts are part of the valve cover and should not be removed.

Loosen the 17 fasteners in the sequence shown and remove the LH valve cover and gasket.

-

Clean and inspect the sealing surfaces with silicone gasket remover and Motorcraft metal surface prep. Follow the directions on the packaging.

-

Discard the valve cover gasket. Clean the valve cover gasket groove with soap and water or a suitable solvent.