F 450 4WD Super Duty V8-6.4L DSL Turbo (2008)
Service Port HVAC: Description and Operation
SERVICE GAUGE PORT VALVES
The high-pressure service gauge port valve is located on the compressor-to-condenser discharge line near the condenser fitting.
The low-pressure service gauge port valve is located on the suction accumulator outlet tube.
The fitting is an integral part of the refrigeration line or component.
-
Special couplings are required for both the high-side and low-side service gauge ports.
-
A very small amount of leakage will always be detectable around the Schrader-type valve with the service gauge port valve cap removed, this is
considered normal. A new Schrader-type valve core can be installed if the seal leaks excessively.
-
The service gauge port valve caps are used as primary seals in the refrigerant system to prevent leakage through the Schrader-type valves from
reaching the atmosphere. Always install and tighten the A/C service gauge port valve caps to the correct torque after they are removed.