F 550 2WD Super Duty V10-6.8L VIN Z Bi-Fuel (2001)
Compressor Fitting HVAC: Service and Repair
Auxiliary Climate Control
REMOVAL
1. Perform the Refrigerant Discharging and Recovery Procedure.
2. Disconnect the auxiliary line fitting.
3. Disconnect the manifold and tube fitting at the suction accumulator/drier.
4. Remove the tube clamp.
5. Remove the eight pin-type retainers and the sight shield.