ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

With Auxiliary Climate Control|Page 6243 > < With Auxiliary Climate Control|Page 6241
Page 1
background image

Accumulator HVAC: Service and Repair
Without Auxiliary Climate Control

REMOVAL

1. Recover the refrigerant.

2. Disconnect the A/C cycling switch connector.

3. Disconnect the evaporator core outlet tube.

CAUTION:  To prevent damage to the fitting and the tube, use a backup wrench when removing the suction accumulator/drier.

4. Disconnect the manifold and tube assembly.

5. Remove the suction accumulator/drier bracket clamp bolts and remove the suction accumulator/drier.

With Auxiliary Climate Control|Page 6243 > < With Auxiliary Climate Control|Page 6241