2. Disconnect the A/C cycling switch connector.

3. Disconnect the evaporator core outlet tube.

CAUTION:  To prevent damage to the fitting and the tube, use a backup wrench when removing the suction accumulator/drier.

4. Disconnect the auxiliary line fitting.

5. Disconnect the manifold and tube assembly.