shorted to ground, module-to-module and module-to-tester communication is not possible. If the high speed CAN data minus is shorted to ground or
an open exists on either bus line, module-to-module and module-to-tester communication is marginal at best. The high speed CAN bus may remain
operational when one of the two termination resistors are not present. Check circuits 1908 (WH) and 1909 (BK) between the TCM C168 and the data
link connector (DLC) C251. The total resistance values must not be more than 5 ohms. If the resistance is more than 5 ohms there is an open in one of
the high speed CAN circuits, damage to the DLC C251, damage to the TCM C168, or a problem in an in-line connector.
Possible Causes
-
high speed CAN circuit 1908 (WH) or 1909 (BK) open
-
TCM C168
-
TCM
Test E: The Instrument Cluster Does Not Respond To The Diagnostic Tool
PINPOINT TEST E: THE INSTRUMENT CLUSTER DOES NOT RESPOND TO THE DIAGNOSTIC TOOL
E1