Page 4
background image

Remove the 8 bolts from the mechatronic unit.

13. CAUTION:  Do not touch the electrical connector pins. Electrostatic charge may occur and will cause damage to the mechatronic unit.

Remove the mechatronic unit from the transaxle.

14. NOTE:  The 5 feed tubes may stick in the case or the mechatronic assembly, make sure that all 5 feed tubes are removed.

NOTE:  Note the location and size of the 5 feed tubes for reassembly.

Remove all of the 5 feed tubes.
1

Remove the clutch (manual valve) supply feed tube.

2

Remove the primary pressure feed tube.

3

Remove the secondary pressure feed tube.

4

Remove the main (pump) pressure feed tube (smaller tube).

5

Remove and discard the torque converter clutch pressure feed tube.