ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 4574 > < Initial Inspection and Diagnostic Overview|Page 4572
Page 1
background image

Auxiliary Power Outlet: Pinpoint Tests

Pinpoint Test A: The DC/AC Inverter Does Not Operate Correctly - No Power At The AC Power
Point/The AC Power Point LED Indicato

High-Voltage Converter/Inverter

Pinpoint Tests

Pinpoint Test A: The DC/AC Inverter Does Not Operate Correctly - No Power at the AC Power Point/The AC Power Point LED Indicator
Flashes with the Key in the ON Position

Refer to Wiring Diagram Set 12, Charging System for schematic and connector information.  See: Diagrams/Electrical Diagrams/Diagrams By Number

Normal Operation

The DC/AC inverter receives 12 volts DC on circuits SBP04 (GN/RD) and CBP35 (YE/GY) and is grounded on circuit GD148 (BK/GY). The incoming
DC power is internally converted to 60 cycle 110 volts AC power that is output to the AC power point on circuits HYA01 (OG/GN) (power) and
HYA02 (OG/WH) (neutral).

NOTE: The electrical device that is powered by the AC power point must not exceed 150 watts.

NOTE: If the green LED is flashing, the AC power point may be overloaded, overheated or shorted. Unplug the electrical device from the AC power
point and cycle the key. Refer to the Owner's Literature to determine if the electrical device is appropriate for the AC power point.

This pinpoint test is intended to diagnose the following:

-

Fuses

-

Circuits

-

DC/AC inverter

-

AC power point

PINPOINT TEST A: THE DC/AC INVERTER DOES NOT OPERATE CORRECTLY - NO POWER AT THE AC POWER POINT/THE AC
POWER POINT LED INDICATOR FLASHES WITH THE KEY IN THE ON POSITION

NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the
connector.

-------------------------------------------------
A1 CHECK CIRCUITS SBP04 (GN/RD) AND CBP35 (YE/GY) FOR VOLTAGE

-

Ignition OFF.

-

Disconnect: DC/AC Inverter C4210A.

-

Ignition ON.

-

Measure the voltage between DC/AC inverter C4210A-1, circuit SBP04 (GN/RD), harness side and ground.

-

Measure the voltage between DC/AC inverter C4210A-3, circuit CBP35 (YE/GY), harness side and ground.

-

Are the voltages greater than 10 volts?

Yes

GO to A2.

No

CHECK the Smart Junction Box (SJB) fuses 4 (30A) and 35 (10A). If OK, REPAIR the circuit(s). TEST the system for normal operation.

Initial Inspection and Diagnostic Overview|Page 4574 > < Initial Inspection and Diagnostic Overview|Page 4572