Ignition OFF.

-

NOTE: Measurements are taken with the fuses installed.

-

Measure the voltage between the SJB fuse 5 (10A) and ground.

-

Is the voltage greater than 10 volts?

Yes

GO to J2.

No

VERIFY the SJB fuse 5 (10A) is OK. If OK, GO to J4. If not OK, REFER to the Wiring Diagrams to identify the possible causes of the circuit short.
REPEAT the network test with the scan tool.

-------------------------------------------------
J2 CHECK THE SJB GROUND CIRCUITS FOR AN OPEN

-

Disconnect: Negative Battery Cable.

-

Disconnect: SJB C2280d.

-

Measure the resistance between the SJB C2280d-8, circuit GD133 (BK), harness side and ground; and between the SJB C2280d-12, circuit
GD133 (BK), harness side and ground.

-

Are the resistances less than 5 ohms?

Yes

GO to J3.

No

REPAIR the circuit. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
J3 CHECK THE MS-CAN CIRCUITS BETWEEN THE SJB AND THE
DLC FOR AN OPEN

-

Disconnect: SJB C2280b.

-

Measure the resistance between the SJB C2280b-37, circuit VDB06 (GY/OG), harness side and the Data Link Connector (DLC) C251-3, circuit
VDB06 (GY/OG), harness side.