ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Emergency Contact Module > < Procedures|Page 60
Page 2
background image

Removal and Installation

1. NOTE: It is necessary to record the current Accessory Protocol Interface Module (APIM) software and hardware level when a new APIM is being

installed to make sure that the new component is the same version as the component being replaced.

Retrieve and record the current APIM software and hardware level. For additional information, refer to Accessory Protocol Interface Module
(APIM) Software Level Check  See: Procedures/Accessory Protocol Interface Module (APIM) Software Level Check.

2. NOTE: Lower the glove compartment completely to access the connectors.

Disconnect the Universal Serial Bus (USB) cable connector and the APIM electrical connector.

3. Remove the instrument panel right finish panel.

4. Remove the 4 screws and the APIM.

5. To install, reverse the removal procedure.

-

If a new APIM is being installed, program the APIM to the correct software level.

Universal Serial Bus (USB) Cable and Port

Universal Serial Bus (USB) Cable and Port

Removal and Installation

1. NOTE: Lower the glove compartment completely to access the connector.

Disconnect the Universal Serial Bus (USB) cable from the Accessory Protocol Interface Module (APIM).

2. Remove the instrument panel center finish panel.

3. Release the pin-type retainers and remove the USB cable and port.

4. To install, reverse the removal procedure.

Emergency Contact Module > < Procedures|Page 60