Focus L4-2.3L VIN Z (2003)
Expansion Block/Orifice Tube: Description and Operation
A/C EVAPORATOR CORE ORIFICE
The A/C evaporator core orifice has the following characteristics:
-
It is located in the rear condenser to evaporator tube and can be removed through an access fitting.
-
It has filter screens located on the inlet and outlet ends of the tube body.
-
The inlet filter screen acts as a strainer for the liquid refrigerant flowing through the A/C evaporator core orifice.
-
O-ring seals on the A/C evaporator core orifice prevent the high-pressure liquid refrigerant from bypassing the A/C evaporator core orifice.
-
Adjustment or repair cannot be made to the A/C evaporator core orifice assembly. It must be serviced as a unit.