Engine Emission Control - 1.8L Duratec-HE (MI4)/2.0L Duratec-HE (MI4) - Crankcase Vent Oil Separator Focus 2004.75 (07/2004-)
Removal and Installation

Removal

  1. Remove the intake manifold.
    For additional information, refer to: Intake Manifold (303-01C Engine - 1.8L Duratec-HE (MI4)/2.0L Duratec-HE (MI4), In-vehicle Repair).

  1. Disconnect the positive crankcase ventilation (PCV) hose from the PCV valve.

  1. Remove the PCV valve from the crankcase vent oil separator.
    1. Push in the locking tangs.
    1. Twist the PCV valve to remove.

  1. Remove the crankcase vent oil separator.
    • Discard the gasket.

Installation

  1. NOTE:
    NOTE:Install a new crankcase vent oil separator gasket.
    NOTE:
    NOTE:Make sure that the PCV hose is clean and free from any oil residue as this will reduce the installation grip of the PCV hose.
    To install, reverse the removal procedure.

Exhaust Gas Recirculation (EGR) Valve > < Engine Emission Control