ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Expansion Block/Orifice Tube|Service Precautions|Page 7367 > < Expansion Block/Orifice Tube|Service Precautions
Page 1
background image

Expansion Block/Orifice Tube: Description and Operation

EVAPORATOR CORE ORIFICE TUBE

NOTE:  A new evaporator core orifice tube should be installed whenever a new A/C compressor is installed.

The A/C evaporator core orifice has the following characteristics:

-

It is color-coded orange.

-

It is located in the condenser to evaporator line.

-

It has filter screens located on the inlet and outlet ends of the tube body.

-

The inlet filter screen acts as a strainer for the liquid refrigerant flowing through the evaporator core orifice tube.

-

O-ring seals on the evaporator core orifice tube prevent the high-pressure liquid refrigerant from bypassing the evaporator core orifice tube.

-

It can be accessed through a fitting in the condenser to evaporator line.

-

Adjustment or service cannot be carried out to the evaporator core orifice tube. A new evaporator core orifice must be installed.

Expansion Block/Orifice Tube|Service Precautions|Page 7367 > < Expansion Block/Orifice Tube|Service Precautions