ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Heater Core > < Expansion Block/Orifice Tube|Description and Operation
Page 1
background image

Expansion Valve: Service and Repair

THERMOSTATIC EXPANSION VALVE

Removal and Installation

1. Recover the refrigerant.
2. Disconnect the A/C pressure transducer electrical connector and detach the wire harness from the thermostatic expansion valve (TXV) stud.
3. Remove the TXV fitting nut and disconnect the fitting.

-

Discard the gasket seals.

-

To install, tighten to 15 Nm (11 lb-ft).

4. Remove the 2 TXV bolts.
5. Remove the TXV.

-

Discard the gasket seals.

6. To install, reverse the removal procedure.

-

Install new gasket seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

7. Evacuate, leak test and charge the refrigerant system.