Expansion Block/Orifice Tube: Service and Repair

Thermostatic Expansion Valve

Removal and Installation

1. Recover the refrigerant.

2. Disconnect the A/C pressure transducer electrical connector and detach the wire harness from the Thermostatic Expansion Valve (TXV) stud.

3. Remove the TXV fitting nut and disconnect the fitting.

-

Discard the gasket seals.

-

To install, tighten to 15 Nm (133 lb-in).

4. Remove the 2 TXV bolts.

5. Remove the TXV.

-

Discard the gasket seals.

6. To install, reverse the removal procedure.

-

Install new gasket seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

7. Evacuate, leak test and charge the refrigerant system.