Fusion FWD V6-3.0L (2009)
Expansion Block/Orifice Tube: Service and Repair
Thermostatic Expansion Valve
Removal and Installation
1. Recover the refrigerant.
2. Disconnect the A/C pressure transducer electrical connector and detach the wire harness from the Thermostatic Expansion Valve (TXV) stud.
3. Remove the TXV fitting nut and disconnect the fitting.
-
Discard the gasket seals.
-
To install, tighten to 15 Nm (133 lb-in).
4. Remove the 2 TXV bolts.
5. Remove the TXV.
-
Discard the gasket seals.
6. To install, reverse the removal procedure.
-
Install new gasket seals.
-
Lubricate the refrigerant system with the correct amount of clean PAG oil.
7. Evacuate, leak test and charge the refrigerant system.