LTD Crown Victoria V8-302 5.0L VIN F FI (1986)
Cabin Temperature Sensor / Switch: Adjustments
ATC TEMPERATURE SENSOR CALIBRATION
CALIBRATION
1. Remove the instrument panel pad.
2. Move the temperature selector lever to the 75° F position.
ATC Temperature Sensor
3. The control arm of the ATC sensor should be aligned with the arrow on the sensor body.
ATC System Temperature Calibration
4. If the arrow is not aligned, loosen the cable housing-to-sensor attaching screw and align the sensor control arm with the arrow while maintaining
the 75° F position of the temperature selector lever.
5. Retighten the cable housing-to-sensor attaching screw, making sure the temperature control stays at 75° F and the sensor arm stays locked.
READJUSTING SENSOR CALIBRATION POINT
NOTE: If it should become necessary to change the calibration point to suit a customer, first check the sensor calibration as described in the above
procedure. If OK, use the following procedure:
1. Establish the customer's preference and the difference between the present and desired comfort level setting.