Refrigerant Oil: Capacity Specifications

REFRIGERANT OIL CAPACITY

TOTAL SYSTEM CAPACITY .............................................................................................................................................................  207 ml (7.0 oz) 

A/C COMPRESSOR

Add the same amount drained, plus the amount collected during refrigerant recovery.

SUCTION ACCUMULATOR OR RECEIVER/DRIER

Add the quantity of oil drained, plus the amount collected during refrigerant recovery and 60 ml (2.0 fl oz).

EVAPORATOR CORE .......................................................................................................................................................................  45 ml (1.5 fl oz.) 

CONDENSER CORE ..........................................................................................................................................................................  60 ml (2.0 fl oz.) 

EVAPORATOR CORE ORIFICE OR THERMOSTATIC EXPANSION VALVE

The amount collected during refrigerant recovery

A/C PRESSURE RELIEF VALVE ......................................................................................................................................................  60 ml (2.0 fl oz.)

REFRIGERANT HOSE/LINE .............................................................................................................................................................  60 ml (2.0 fl oz.)

NOTE:  If an excessive amount of refrigerant oil is lost due to a hose rupture/separation or other damage, the total system refrigerant oil capacity must
be added.

O-RING LEAK REPAIR .....................................................................................................................................................................  60 ml (2.0 fl oz.)

NOTE:  The amount specified may be used for one or multiple O-ring leak repairs. Do not multiply the refrigerant oil amount by the number of
O-ring leaks being repaired.

SERVICE PORT LEAK REPAIR .......................................................................................................................................................  60 ml (2.0 fl oz.)