Radiator Cooling Fan Motor: Service and Repair

Cooling Fan Motor and Shroud

Removal and Installation

1. Disconnect the battery ground cable.
2. Remove the degas bottle or coolant expansion tank.

3. Disconnect the cooling fan electrical connector.

4. Separate the fan harness from the shroud.

5. Remove the LH bolt.

6. Remove the RH bolt.