Accumulator HVAC: Service and Repair

SUCTION ACCUMULATOR

Removal and Installation

NOTE:  Installation of a new suction accumulator is not required when repairing the A/C system, except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator.

1. Recover the refrigerant.
2. Disconnect the suction accumulator inlet fitting.

-

Discard the O-ring seals.

3. Disconnect the suction accumulator outlet fitting.

-

Discard the O-ring seals.

4. Remove the 2 suction accumulator bolts.
5. Remove the suction accumulator.

6. NOTE:  Care should be taken to minimize exposure of the suction accumulator desiccant to the atmosphere. Do not remove the shipping caps

from the new suction accumulator until immediately before the line fittings are to be attached.

To install, reverse the removal procedure.
-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.