ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Suction Accumulator|Page 6776 > < Accumulator HVAC|Description and Operation
Page 1
background image

Accumulator HVAC: Service and Repair
Suction Accumulator

SUCTION ACCUMULATOR

Removal and Installation

NOTE:  Installation of a new suction accumulator is not required when repairing the air conditioning system, except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator.

1. Recover the refrigerant.
2. Disconnect the suction accumulator inlet fitting.

-

Discard the O-ring seals.

3. Disconnect the suction accumulator outlet fitting.

-

Discard the O-ring seals.

4. Remove the 2 suction accumulator bolts.
5. Remove the suction accumulator.
6. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

7. Evacuate, leak test and charge the refrigerant system.

Suction Accumulator|Page 6776 > < Accumulator HVAC|Description and Operation