SUCTION ACCUMULATOR
Removal and Installation
NOTE: Installation of a new suction accumulator is not required when repairing the air conditioning system, except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator.
1. Recover the refrigerant.
2. Disconnect the suction accumulator inlet fitting.
-
Discard the O-ring seals.
3. Disconnect the suction accumulator outlet fitting.
-
Discard the O-ring seals.
4. Remove the 2 suction accumulator bolts.
5. Remove the suction accumulator.
6. To install, reverse the removal procedure.
-
Install new O-ring seals.
-
Lubricate the refrigerant system with the correct amount of clean PAG oil.
7. Evacuate, leak test and charge the refrigerant system.