INSTALLATION
1. Install suction line support bracket on evaporator to compressor suction line.
2. Route new evaporator to compressor suction line with protective caps installed.
3. Remove protective caps and connect new evaporator to compressor suction line into system using new O-ring seals lubricated with clean
Motorcraft YN-12b refrigerant oil or equivalent meeting Ford specification WSH-M1C231-B. Connect spring lock coupling.
4. Install suction line support bracket to engine with retaining nut.
5. Leak-test, evacuate and charge the system. Observe all safety precautions. See: Service and Repair
6. Install radiator upper sight shield.