Mustang Cobra V8-281 4.6L DOHC VIN V MFI (1997)
Multiplex Communication Network: Initial Inspection and Diagnostic Overview
Inspection and Verification
1.Verity the customer's original concern.
2.Inspect to determine if one of the following electrical concerns apply:
VISUAL INSPECTION CHART
Electrical
-
check electrical connections for obvious damage, opens or shorts.
3. Inspect Pin 2, Pin 7 and Pin 10 on the Data Link Connector (DLC) for loose, bent, deformed, corroded or broken pins. If pin is damaged, service
or replace pin, verify communication with Rotunda New Generation Star (NGS) Tester or equivalent.
4. If the concern(s) remains after the inspection, continue with NGS Tester Driven Diagnostics. See: Scan Tool Testing and Procedures