Mustang Cobra V8-281 4.6L DOHC VIN V MFI (1997)
Canister Purge Control Valve: Service and Repair
Typical Canister Venting System
REMOVAL and INSTALLATION
1. Raise vehicle on hoist.
2. Remove evaporative emission canister. Remove evaporative emission canister bracket (if required).
3. Lower vehicle.
4. Disconnect canister purge control valve from engine control sensor wiring at connector.
5. Disconnect evaporative emissions hose from upper intake manifold and remove evaporative emissions hose and canister purge control valve as an
assembly.
6. If required, remove canister purge control valve from evaporative emission hose.
7. To install, reverse removal procedure.