Mustang Cobra V8-281 4.6L DOHC VIN V MFI (1997)
2. Install the Rotunda Check Tool and Gasket 014-R1075 or equivalent into the torque converter hub.
3. Install the torque converter into a press with flywheel studs facing up.
4. Apply enough pressure from the press to seal the tool into the hub of the torque converter.
5. Connect air hose to the tool, apply maximum 80 psi.