Ranger 2WD V6-245 4.0L VIN X SFI (1997)
![background image](/ford/ranger_2wd/v6-245_4.0l_vin_x_sfi/Page-1820001.png)
Torque Converter: Component Tests and General Diagnostics
Leak Check
1. Clean the outside surface at the torque converter.
2. Install Torque Converter Leak Check Tool and Gasket 014-R1075 into converter hub.
3. Install torque converter with installed Torque Converter Leak Check Tool and Gasket 014-R 1075 into press.
4. Secure press. Apply enough force from press to seal tool into torque converter.
WARNING: ALWAYS FOLLOW PROPER SAFETY PROCEDURES WHILE USING PRESS.
5. Apply air pressure 80 psi (MAX) to valve on Torque Converter Leak Check Tool and Gasket 014-R1075.
NOTE: Use clean dry shop air.