ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Cleaning|Page 6253 > < Cleaning|Page 6251
Page 2
background image

4. Use a 10 mm socket to remove the M6 x 30 mm manual valve detent spring screw. Remove the manual valve detent spring.

5. Use a 10 mm socket to remove the four M6 x 20 mm low/reverse servo cover screws. Remove the low/reverse servo cover, gasket and the servo

piston and rod assembly.

6. Use a 10 mm socket to remove the sixteen M6 x 40 mm, four M6 x 45 mm, two M6 x 35 mm and one M6 x 30 mm main control valve body

screws.

CAUTION:  Support main control valve body.