ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 5442 > < Initial Inspection and Diagnostic Overview|Page 5440
Page 2
background image

3. Lift up on the end play checking tool and note the dial indicator reading. If the reading exceeds end play limits, replace the torque converter.

Leak Check

1. Clean the outside surface of the torque converter.

2. Install Torque Converter Leak Check Tool and Gasket into converter hub.

3. Install the torque converter with the installed leak check tool into the Arbor press.

WARNING:  ALWAYS FOLLOW PROPER SAFETY PROCEDURES WHILE USING PRESS. 

Secure the press. Apply enough force from the press to seal tool into the torque converter.

Initial Inspection and Diagnostic Overview|Page 5442 > < Initial Inspection and Diagnostic Overview|Page 5440