Daytime Running Lamp: Initial Inspection and Diagnostic Overview

Special Tool(s) Used With Diagnostics

Daytime Running Lamps (DRL)

Principles of Operation

Daytime Running Lamps (DRL)

Principles of Operation

NOTE:  The Smart Junction Box (SJB) is also known as the Generic Electronic Module (GEM).

NOTE:  The Daytime Running Lamps (DRL) is not a programmable parameter for this vehicle.

The DRL are controlled by the SJB. The SJB operates the low beam headlamps at a reduced intensity when the following conditions are met:

-

The high beam headlamps are not on

-

The ignition switch is in the RUN position

-

The parking brake is not engaged

Field-Effect Transistor (FET) Protection

Field-Effect Transistor (FET) is a type of transistor that when used with module software can be used to monitor and control current flow on module
outputs. The FET protection strategy is used to prevent module damage in the event of excessive current flow.

The SJB utilizes an FET protective circuit strategy for many of its outputs (for example, a headlamp output circuit). Output loads (current level) are
monitored for excessive current (typically short circuits) and are shut down (turns off the voltage or ground provided by the module) when a fault event
is detected. A continuous DTC is stored at the fault event and a cumulative counter is started.

When the demand for the output is no longer present, the module resets the FET circuit protection to allow the circuit to function. The next time the
driver requests a circuit to activate that has been shut down by a previous short (FET protection) and the circuit remains shorted, the FET protection
shuts off the circuit again and the cumulative counter advances.

When the excessive circuit load occurs often enough, the module shuts down the output until a repair procedure is carried out. Each FET protected
circuit has 3 predefined levels of short circuit tolerance based on the harmful effect of each circuit fault on the FET and the ability of the FET to
withstand it. A module lifetime level of fault events is established based upon the durability of the FET. If the total tolerance level is determined to be
600 fault events, the 3 predefined levels would be 200, 400 and 600 fault events.

When each tolerance level is reached, the continuous DTC that was stored on the first failure cannot be cleared by a command to clear the continuous
DTCs. The module does not allow this code to be cleared or the circuit restored to normal operation until a successful self-test proves that the fault has
been repaired. After the self-test has successfully completed (no on-demand DTCs present), DTC B106E and the associated continuous DTC (the DTC
related to the shorted circuit) automatically clears and the circuit function returns.

When the first or second level is reached, the continuous DTC (associated with the short circuit) sets along with DTC B106E. These DTCs can be
cleared using the module on-demand self-test, then the Clear DTC operation on the scan tool (if the on-demand test shows the fault corrected). The
module never resets the fault event counter to zero and continues to advance the fault event counter as short circuit fault events occur.

If the number of short circuit fault events reach the third level, then DTCs B106F and B1342 set along with the associated continuous DTC. This DTC
cannot be cleared and the module must be replaced.

The SJB FET protected output is the DRL output within the SJB. The low beam circuit themselves are protected by SJB fuses 3 (10A) and 4 (10A).