ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Accumulator HVAC|Locations|Page 7513 > < Accumulator HVAC|Locations|Page 7511
Page 1
background image

Accumulator HVAC: Service and Repair

REMOVAL

1. Perform the Refrigerant Discharging and Recovery Procedure.

2. Disconnect the A/C cycling switch electrical connector.

3. Disconnect the suction accumulator refrigerant lines.

^

Discard the O-ring seals.

CAUTION:  Use a back-up wrench to prevent damage to the tubes.

4. Remove the three suction accumulator bracket screws and the suction accumulator.

INSTALLATION

1. To install, reverse the removal procedure.

^

If a new suction accumulator is to be installed, transfer the A/C cycling switch to the new suction accumulator.

^

Lubricate the refrigerant system with the correct amount of clean PAG oil or equivalent. See: Refrigerant Oil Addition.

^

Install new O-ring seals lubricated in clean PAG oil or equivalent.

2. Evacuate, leak test, and charge the refrigerant system.

Accumulator HVAC|Locations|Page 7513 > < Accumulator HVAC|Locations|Page 7511