Compressor Fitting HVAC: Service and Repair

REMOVAL

NOTE:  Replacement of the suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of
system contamination from a failed A/C compressor or damage to the suction accumulator.

1. Recover the refrigerant.

2. Disconnect the electrical connector.

3. Disconnect the compressor manifold and tube assembly from the A/C compressor.

1

Loosen the bolt.

2

Disconnect and position aside the compressor manifold and tube assembly.
^

Discard the O-ring seals.

4. Disconnect the compressor manifold and tube assembly spring lock coupling from the suction accumulator.

-

Discard the O-ring seals.