Ranger 4WD V6-245 4.0L (1991)
5.
Loosen fitting connecting accumulator to evaporator core.
6.
Remove lower forward screw holding flanges of case and bracket together, and remove screw holding evaporator inlet tube to the accumulator
bracket. Disconnect accumulator from evaporator core, then remove bracket from accumulator/dryer.
7.
Reverse procedure to install. Use new O-rings lubricated with refrigerant oil.
8.
Leak test, evacuate and charge system. Check system for proper operation.