Ranger 4WD V6-245 4.0L VIN X SFI (1999)
2
Remove the valve body separator plate screws.
5. Remove valve body separator plate and main control to separating plate gasket.
1
Remove valve body separator plate.
2
Remove main control to separator plate gasket and discard.
6. Remove the extension housing lube orifice and the metal silver Electronic Pressure Control (EPC) limit relief valve and spring.
1
Remove the extension housing lube orifice.
2
Remove the silver metal EPC limit relief valve and spring.
7. Remove the black plastic converter relief valve and spring.
8. Remove the Electronic Pressure Control (EPC) limit circuit screen.