Ranger 4WD V6-4.0L (2009)
Hose/Line HVAC: Service and Repair
Condenser to Evaporator Line
Condenser to Evaporator Line
Removal and Installation
1. Recover the refrigerant.
2. Disconnect the evaporator inlet fitting.
-
Discard the O-ring seals.
3. Remove the condenser outlet fitting nut and disconnect the fitting.
-
Discard the O-ring seal.
-
To install, tighten to 8 Nm (71 lb-in).
4. To install, reverse the removal procedure.
-
Install new O-ring seals.
-
Lubricate the refrigerant system with the correct amount of clean PAG oil.
5. Evacuate, leak test and charge the refrigerant system.