B9 CHECK THE 4X4 CONTROL MODULE

-

Disconnect: 4X4 Control Module C281a.

-

Measure the resistance between the SJB C2280c-2, circuit CPL12 (VT/OG), harness side and ground.

-

Is the resistance greater than 10,000 ohms?

Yes

GO to B18.

No

REPAIR the circuit. TEST the system for normal operation.

-------------------------------------------------
B10 CHECK THE RH FRONT DOOR AJAR SWITCH FOR A SHORT TO GROUND

-

Disconnect: RH Front Door Ajar Switch C602.

-

Enter the following diagnostic mode on the scan tool: SJB DataLogger.

-

Monitor the SJB RH front door ajar switch PID (P_DR_SW).

-

Did the door ajar PID change with the switch disconnected?

Yes

INSTALL a new door ajar switch. TEST the system for normal operation.

No

GO to B11.

-------------------------------------------------
B11 CHECK CIRCUIT CPL31 (WH) FOR A SHORT TO GROUND

-

Ignition OFF.

-

Disconnect: SJB C2280d.

-

Measure the resistance between the RH front door ajar switch C602-1, circuit CPL31 (WH), harness side and ground.

-

Is the resistance greater than 10,000 ohms?

Yes

GO to B16.

No

REPAIR the circuit. TEST the system for normal operation.