Taurus V6-182 3.0L VIN 1 FI Flex Fuel (1997)
Coupler HVAC: Description and Operation
Peanut Fitting
The A/C condenser core uses peanut shaped refrigerant fittings instead of spring lock couplings.
^
The male and female blocks of the peanut fitting are retained with a nut.
^
An O-ring seal is installed around the tube on the male block.
^
The female block is welded to the tube and is not adjustable.
^
Support the female fitting with a wrench to prevent twisting of the tubes.
^
The male block will pivot around the tube to allow for alignment with the female block during assembly.
^
When properly assembled the male and female fittings should be flush.