ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

California Emissions|Page 5085 > < Air Diverter Valve|Description and Operation
Page 1
background image

Air Diverter Valve: Service and Repair
California Emissions

Secondary Air Injection

REMOVAL and INSTALLATION

1. Remove air cleaner outlet tube.
2. Disconnect main emission vacuum control connector from secondary air injection diverter valve.
3. Completely loosen the secondary air injection manifold tube nut from the secondary air injection diverter valve.
4. Disconnect secondary air injection pump outlet hose from the secondary air injection diverter valve.
5. Remove two retaining bolts and the secondary air injection diverter valve.
6. If required, remove the secondary air injection manifold tube from the exhaust manifolds.
7. Reverse procedure to install. Tighten retaining bolts for diverter valve to 15-20 Nm (12-14 lb ft). Tighten secondary air injection manifold tube

nuts to 26-34 Nm (20-25 lb ft). Tighten engine air cleaner tube clamps to 2 Nm (18 lb in).