ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Brakes and Traction Control > < Transmission Temperature Sensor/Switch, A/T|Specifications
Page 1
background image

Transmission Temperature Sensor/Switch: Description and Operation

PURPOSE

The Powertrain Control Model (PCM) measures the voltage across the Transmission Fluid Temperature (TFT) sensor to determine the
temperature of the transmission fluid. The PCM uses this information to determine whether a cold start shift schedule is necessary. The cold start
shift schedule allows quicker shifts when the transmission fluid is cold.

CONSTRUCTION

The TFT sensor is a thermistor type device located on the transmission main control valve body.

Transmission Fluid Temperature (TFT) Schematic

OPERATION

The PCM supplies a 5.0 volt reference voltage to the TFT sensor. The sensor resistance lowers as the fluid temperature increases. This resistance
variation results in a change in the voltage drop across the TFT and a corresponding change in the signal sent to the PCM.

RELATED DIAGNOSTIC TROUBLE CODES

DTC 26/636 - TFT sensor output was beyond self-test range.

DTC 56/637 - TFT sensor output was greater than the self-test maximum of 4.8 volts.

DTC 66/638 - TFT sensor output was below the self-test minimum value of 0.15 volts.

DTC 68/657 - TFT sensor output indicates that a transmission over temperature condition occurred.

Brakes and Traction Control > < Transmission Temperature Sensor/Switch, A/T|Specifications