ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2655 > < Initial Inspection and Diagnostic Overview
Page 2
background image

ISO 9141 Network Communication Fault Chart

Medium Speed Controller Area Network (MS-CAN)

The MS-CAN uses an unshielded twisted pair cable of data (+) and data (-) circuits. The data (+) and the data (-) circuits are each regulated to
approximately 2.5 volts during neutral or rested network traffic. As bus messages are sent on the data (+) circuit, voltage is increased by approximately
1.0 volt. Inversely, the data (-) circuit is reduced by approximately 1.0 volt when a bus message is sent. Multiple bus messages can be sent over the
network CAN circuits allowing multiple modules to communicate with each other for general information transfer. The MS-CAN will not communicate
while certain faults are present, but will operate with diminished performance with other faults present. The MS-CAN bus may remain operational when
1 of the 2 termination resistors are not present.

In the event that 1 of the 2 network circuits (MS-CAN + or MS-CAN -) becomes open to a module on the network, unreliable network communication to
all modules on the network may result. The module to which the network circuit is open may repeatedly send network messages indicating there has been
partial data received. This type of message is referred to as a Negative-Acknowledge (NACK) message. Repeated NACK messages may "load" the
network with too much activity causing intermittent no communication to other network modules and/or the scan tool.

The following fault chart describes the specific MS-CAN failures and their resulting symptom:

MS-CAN Communication Fault Chart

High Speed Controller Area Network (HS-CAN)

The HS-CAN uses an unshielded twisted pair cable of data (+) and data (-) circuits. The data (+) and the data (-) circuits are each regulated to
approximately 2.5 volts during neutral or rested network traffic. As bus messages are sent on the data (+) circuit, voltage is increased by approximately
1.0 volt. Inversely, the data (-) circuit is reduced by approximately 1.0 volt when a bus message is sent. Multiple bus messages can be sent over the
network CAN circuits allowing multiple modules to communicate with each other for real time information transfer and control. The HS-CAN will not
communicate while certain faults are present, but will operate with diminished performance with other faults present. The HS-CAN bus may remain
operational when 1 of the 2 termination resistors are not present. The

In the event that 1 of the 2 network circuits (HS-CAN + or HS-CAN -) becomes open to a module on the network, unreliable network communication to
all modules on the network may result. The module to which the network circuit is open may repeatedly send network messages indicating there has been
partial data received. This type of message is referred to as a Negative-Acknowledge (NACK) message. Repeated NACK messages may "load" the
network with too much activity causing intermittent no communication to other network modules and/or the scan tool.

The following fault chart describes the specific HS-CAN failures and their resulting symptom:

Initial Inspection and Diagnostic Overview|Page 2655 > < Initial Inspection and Diagnostic Overview