ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2749 > < Initial Inspection and Diagnostic Overview|Page 2747
Page 77
background image

-------------------------------------------------
U29 CHECK FOR CORRECT DSM OPERATION

-

Disconnect all the DSM connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the DSM connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new DSM. CONNECT all modules. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CONNECT all modules. CLEAR
the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
U30 CHECK FOR CORRECT SJB OPERATION

-

Disconnect all the SJB connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the SJB connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new SJB. CONNECT all modules. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CONNECT all modules. CLEAR
the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
U31 CHECK FOR CORRECT RETM OPERATION

-

Disconnect the RETM connector.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect the RETM connector and make sure it seats correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new RETM. CONNECT all modules. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CONNECT all modules. CLEAR
the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
U32 CHECK FOR CORRECT HVAC MODULE OPERATION

Initial Inspection and Diagnostic Overview|Page 2749 > < Initial Inspection and Diagnostic Overview|Page 2747