Expansion Block/Orifice Tube: Service and Repair

Evaporator Core Orifice

Removal

1. Recover the refrigerant.

2. Disconnect the evaporator core orifice access fitting.

-

Discard the O-ring seal.

3. Inspect the evaporator core orifice for damage before attempting to remove it from the line.

4. If the evaporator core orifice is intact, engage the Fixed Orifice Remover/Installer. Hold the T-handle stationary while rotating the tool body to

remove the evaporator core orifice.

5. If the evaporator core orifice is broken, screw the end of the Broken Orifice Remover into the broken orifice. Hold the T-handle stationary while

rotating the tool body to remove the evaporator core orifice.