A/C - Blower Motor Won't Turn OFF/One Speed Inop.
TSB 09-19-6
10/05/09
HEATER BLOWER FAN SWITCH - CONTINUOUS
OPERATION / INOPERATIVE ON ONE SPEED
FORD:
2010 Transit Connect
ISSUE
Some 2010 Transit Connect vehicles may exhibit a heater blower fan motor continuously operating, or inoperative on one speed setting. This may be due
to a wire chafe in the 14401 harness, behind the center console.
ACTION
Follow the Service Procedure steps to correct the condition.
SERVICE PROCEDURE
1. Lift the park brake lever upward.
2. Place the selector lever in the neutral position.
3. Remove the selector lever trim panel in the following sequence.
a. Lift the rear of the panel upward, releasing the rear retaining clips.
b. Pull the panel toward the rear of the vehicle releasing the front retaining clips.
4. Confirm touch condition between heater blower switch wiring and instrument panel (IP) bracket. (Figure 1)
5. Repair any chafed wires using approved splicing methods. Refer to Wiring Diagram (WD), Cell 5.