Air Cleaner Outlet Tube: Service and Repair

REMOVAL 

1. Loosen engine air cleaner tube clamps on air cleaner outlet tube.

2. Disconnect crankcase ventilation hose from air cleaner outlet tube fitting.

3. Remove air cleaner outlet tube from mass air flow sensor and throttle body.

INSTALLATION 

1. To install, reverse removal procedure. 

NOTE:  Align arrow mark on air cleaner outlet tube with rib on throttle body.

2. Tighten engine air cleaner tube clamps to 3-5 Nm (27-44 in lb).

Constant Control Relay Module <--> [Integrated Control Relay Module] > < Air Cleaner Outlet Tube <--> [Intake Air Duct]|Specifications